Article 725 Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits - 725.61
 

 
Subject - Article 725 Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits - 725.61
Based on - NEC - 2005 Edition

November 30, 2007
This newsletter was sent to 27599 newsletter subscribers
 

Ask a Question |  Weekly Code GraphicQuizzes |  Free Stuff InstructorsOnline Training Products | Seminars | SubscribeUnsubscribe
[ image1 Post Comments | View Comments | Notify Me When Comments Are Added ] Web Page Version [Printer-Friendly]    
 

Article 725   Hi Res - Cable/DSL [7152Kb]

VIEWING Video FILE requires
Real Media Player [ FREE ]

Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits

725.61 Applications of Class 2 and Class 3 Cables

New sentence identifies the type of nonmetallic raceway containing Class 2 or Class 3 cables that is permitted in “other spaces used for environmental air.”

Class 2, Class 3, and PLTC cables must comply with the requirements of (A) through (H).
(A) Ducts, Plenums and Other Space Used for Environmental Air. Class 2 or Class 3 cables cannot be run in ducts or plenums, even if plenum rated [725.3(B)], but plenum-rated Class 2 or Class 3 cables can be installed above a suspended ceiling or below a raised floor that is used for environmental air.
Figure 725-4

Listed plenum raceways can be installed above a suspended ceiling or below a raised floor used for environmental air [300.22(C)], but only if the cables contained in these raceways are plenum-rated Type CL2P, or CL3P. Figure 725-5

Author’s Comment: Nonplenum-rated Class 2 and Class 3 cables within electrical metallic tubing, as permitted by 300.22(C), can be installed above a suspended ceiling or below


Figure 725-4
(Click on image to enlarge)


Figure 725-5
(Click on image to enlarge)

     
Click here to post a comment
[ View More Newsletters ] [ Send to a Friend ] [ Post Comments | View Comments | Notify Me When Comments Are Added ]

Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Experiencing a Problem? Click Here

Comments
  • What about plenum rated cable in HVAC equipment? e.g. Mounting a temperature sensors in the air stream or some other sensor. Can we run plenum rated cable to that sensor in the equipment?

    TJB

Reply to this comment
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

This newsletter is closed to new comments.

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter