Article 422 Appliances - 422.16 Flexible Cords
 

 
Subject - Article 422 Appliances - 422.16
Based on - NEC - 2005 Edition Flexible Cords

August 3, 2007
This newsletter was sent to 26461 newsletter subscribers
 

Ask a Question |  Weekly Code GraphicQuizzes |  Free Stuff InstructorsOnline Training Products | Seminars | SubscribeUnsubscribe
[ image1 Post Comments | View Comments | Notify Me When Comments Are Added ] Web Page Version [Printer-Friendly]    

Article 422   Hi Res - Cable/DSL [4432Kb]
VIEWING Video FILE requires
Real Media Player [ FREE ]
Appliances

422.16 Flexible Cords

New rule allows range hoods to be cord-and-plug connected, if they comply with new stringent requirements.

(B) Specific Appliances.
(4) Range Hoods. Range hoods can be cord-and-plug connected, where all of the following conditions are met.
Figure 422-2
(1) The flexible cord terminates with a grounding type attachment plug.
(2) The length of the cord must not be less than 18 in. or longer than 36 in.
(3) The range hood receptacle must be located to avoid physical damage to the flexible cord.
(4) The range hood receptacle must be accessible.
(5) The range hood receptacle must be supplied by an individual branch circuit.



Figure 422-2
(Click on image to enlarge)

       
 

Click here to post a comment
[ View More Newsletters ] [ Send to a Friend ] [ Post Comments | View Comments | Notify Me When Comments Are Added ]

Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Experiencing a Problem? Click Here

Comments
  • Makes perfect sense except why the requirement for individual branch circuit? Is this also a requirement for a "hard wired" range hood? If so this rule is understandably consistent but if not, what is the thinking requiring a dedicated circuit for cord and plug but not for hard wired?

    John McManus

Reply to this comment
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

This newsletter is closed to new comments.

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter