Top 101 NEC Rules – Part 3 of 4

image

If you missed Part 1, you can click here to download it now.

If you missed Part 2, you can click here to download it now.

 

Download Part 3

 

We at Mike Holt Enterprises try to provide as much as we can to the industry at no charge. For this reason we’ve created a free “Top 101 NEC Rules” textbook. The material in this textbook was extracted from Mike's Understanding the 2005 NEC textbook.

 

It’s a quick reference and guide to make sure you’re up to speed on these very important rules.

 

Because of the size of the textbook we’ve decided to make it available in four parts. Last month we made Part 2 available, in May we sent Part 1 and now you can download Part 3:

 

Details of Part 3

Rule 51— 250.94 Grounding (Bonding) of Communications Systems

Rule 52—250.97 Bonding 277V/480V

Rule 53—250.102 Bonding Jumper

Rule 54— 250.104 Bonding of Piping Systems and Exposed Structural Metal

Rule 55—250.106 Lightning Protection System

Rule 56— 250.118 Types of Equipment Grounding (Bonding) Conductors

Rule 57— 250.122 Sizing Equipment Grounding (Bonding) Conductor

Rule 58— 250.142 Use of Grounded Neutral Conductor for Equipment Grounding (Bonding)

Rule 59— 250.146 Connecting Receptacle Grounding Terminal to Box

Rule 60— 250.148 Continuity and Attachment of Equipment Grounding (Bonding)

Conductors to Boxes

Rule 61—300.3 Conductors

Rule 62—300.5 Underground Installations

Rule 63—300.10 Electrical Continuity

Rule 64—300.11 Securing and Supporting

Rule 65—300.12 Mechanical Continuity

Rule 66—300.13 Splices and Pigtails

Rule 67—300.15 Boxes or Conduit Bodies

Rule 68—300.20 Induced Currents in Metal Parts

Rule 69— 300.21 Spread of Fire or Products of Combustion

Rule 70— 300.22 Ducts, Plenums, and Air-Handling Spaces

Rule 71—310.4 Conductors in Parallel

Rule 72—310.15 Conductor Ampacity

Rule 73—312.8 Used for Raceway and Splices

Rule 74— 314.16 Number of 6 AWG and Smaller Conductors in Boxes and Conduit Bodies

Rule 75—314.23 Support of Boxes and Conduit Bodies

 

Click here or on the image above to download Part 3 (7.03 MB), but be advised that this download may take a few minutes to download depending on your internet connection speed. If you encounter a problem opening this file, be sure you have the latest version of Adobe Acrobat installed on your system (click here).

 

We will be sending Part 4 next month, stay tuned.

 

 

 

[ View More Newsletters ] [ Send to a Friend ] [ Please Reply With Your Comments | View Comments | Notify Me When Comments Are Added ]

F o r w a r d   t h i s   N e w s l e t t e r   t o   a   F r i e n d !
Do you have a friend, relative, or colleague who you think would be interested in receiving this free newsletter? If so, we encourage you to forward this message along to them. If you received this email from someone else, and wish to receive your own free issues of our newsletter, sign up today!

C o n t a c t    I n f o r m a t i o n
 

Copyright © 2002, 2003, 2004, 2005, 2006 Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Comments
  • The sizing of emergency generators has always been an important and misunderstood issue. I learned early in my career that a 5 kw generator may not be able to start a 1.5 horsepower well pump. In commercial buildings, the main issues are sizing the generator to operate fire pumps and elevators. If in doubt, size the unit conservatively. If a sales rep is trying to convince you that a smaller generator will work, have him put it in writing and agree to an acceptance test that includes operating all generator loads while starting the largest motor(s). A generator set that cannot perform properly is worse than no generator at all because it gives a false sense of security and may fail at the most critical times. --Jim Cook, PE

    Jim Cook

Reply to this comment
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

This newsletter is closed to new comments.

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter