Electrical Safety  

 

 

Help us help you. Image

We’re constantly getting requests for advice and recommendations about electrical safety, and want to make those resources available to you in one place on our website - not only 70E, but also general knowledge for safety in the workplace.

Attended a good safety class recently? Seen a good video or document? If you have a great resource you’d like to share, please comment below or send an email to paula@mikeholt.com

  • Safety class
  • Reference books
  • Websites
  • Videos
  • Training DVDs
  • PDFs
  • Other….

We’ll follow up on this newsletter once we’ve had a chance to process the feedback and put the links on our Safety webpage.

 

 

 

 

Click Here to Post a Comment Click Here to View Comments Click Here to Unsubscribe
 
Image
 
Visit: Exam Preparation | Continuing Education | Code Products | Newsletters | and more
Copyright© Mike Holt Enterprises of Leesburg, Inc. All Rights Reserved This article is protected by United States copyright laws and may not be published without prior written permission.
Mike Holt Enterprises of Leesburg, Inc. 3604 Parkway Blvd. Suite 3 Leesburg, FL 34748
"... as for me and my house, we will serve the Lord." [Joshua 24:15]
Comments
  • I think large stroage battery installations are too often disregarded as a safety hazard because the voltages are relatively low and the buss bars are uninsulated and exposed. As a matter of fact and accident such as grounding out one these buss bars can cause a flash burn of 1000 amps or more which would of course cause a horrible injury.

    Bob  January 15 2016, 7:33 pm EST
  • Reply from: Roger Risner   January 16 2016, 11:55 am EST
    Hi Bob,

    Flashes are not what I deal with more and more each year, battery backup to open IBC & IFC Special Construction SECTION 3110 Automated Vehicular Gate (UL325/ASTM F2200).

    Local AHJ in Cascade Township, MI had the Master remove the 24vdc from the 120vac 29 CFR 1910.399(3) "custom-made equipment and related installations." install to meet 29 CFR 1910.147 Control of Hazardous Energy.

    Now when the 120vac power is disconnected for Lockout service & maintenance the machines may startup on battery to go into "Fail Safe" or Fail Secure" mode while the 120vac power is off, and upon restore.

    The above gate that killed the 8-year old is the same type and with batter backup the gates in Cascade if triggered by a loop, SOS, Keypad, Card reader, Phone, or even another safety device the system was never locked out.

    The below was sad, many Michigan AHJ's don't inspect for anything other that the UL Label and approve the system without meeting any of the UL325 or ASTM F2200 minimum standards of construction.

    We are looking at putting together an "honest services" fraud against the municipalities that adopted Michigan PA 230 of 1972 by Municipal Ordinance the failed to hire competent officials, Plan Review, Inspections, and Building.

    Municipal Electric Gate Servies (MEGS) Roger Risner 616 318 8031 Roger@Gate-Tek.com JB Maintenance (Michigan Electrical COntractor)

    Thanks ROG