Ronk Blocker
 

 

Topic - Stray Voltage
Subject -Ronk Blocker

February 19, 2010
This newsletter was sent to 19279 newsletter subscribers

Ask a Question |  Continuing EducationQuizzes |  Free Stuff Instructors Products | Seminars | SubscribeUnsubscribe
[ image1 Post Comments | View Comments | Notify Me When Comments Are Added ]  

Ronk Blocker®

Image1Agricultural specialists have known for some time that low non-lethal voltages accessed to dairy animals can cause mastitis, affect animal behavior and materially reduce milk production. More recently, the same voltages have been known to cause problems in swine parlors, poultry houses, water fountains, swimming pools and homes.

Various studies have shown that voltages about 0.5 volts can be detected by animals that are very wet as is a dairy cow being washed down prior to milking. There is some evidence that humans are susceptible to a threshold voltage of approximately 1 volt when they are wet. Thus voltage below 10 volts, which previously the electrical industry has largely ignored as a non-problem, now, has a much greater interest and appreciation.

Since these low voltages may now have many sources, they have been variously called “tingle voltage”, extraneous voltage, or more generically called Stray Voltage. A number of studies and findings have identified methodical and logical methods for identifying the sources of the problems and eliminating them.

Stray voltages can come from many sources, both on and off the site. In most cases, the problems are the result of several sources simultaneous combined. On-site stray voltage can usually be resolved through a program of upgrading and reconnecting the wiring system and its various loads. Off-site stray voltage, which is of particular interest to the power supplier, can result from primary neutral currents, off-site faults, marginal groundings, etc.

Ronk Electrical Industries Inc. has developed the BLOCKER, which is a device designed to reduce the off-site contribution to the stray voltage problem. This simplifies the solution since any remaining problems have to be on-site in nature and can be handled and resolved accordingly.

Click on the image or the following link: The Role of the Ronk BLOCKER®

For additional Information call Ronk Electrical Industries at 1-800-221-7665 or visit their website http://www.ronkelectrical.com/blocker.html.

 

Click here to post a comment

[ Post Your Comments | View Comments | Notify Me When Comments Are Added ]
[ View More Newsletters ]

Bookmark and Share


Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

 

 
Comments
  • When will the electrical industry realize that voltage does not kill? It is current that harms cows and humans. Mike you would do the electrical industry a GREAT favor to get on the band wagon and you can start by showing a picture of a Van de Graaff generator at 400,000 volts and a young gril holding onto the 400,000 volts with her hair standing up.

    I have a copy of such a picture from the internet but do not have the address.

    To just give voltage as the level of harm without including any of the other required parameters is STUPID misleading. The bases for this statement is algebra where to solve any equation you must give values for one less than the number of parameters. Ohms Law had three unknowns therefore you must give values for two of the unknowns in order to solve the problem - That of finding the current.

    However, with electrocution there is a fourth value TIME.

    I have not looked at the instructions of the installation of the Ronk recently but I find that the utilites still install the primary neutral connection to earth on one side of the pole while the seconadry neutral to ground connection is installed on the opposite side negating the effectiveness of the blocker.

    Donald W. Zipse, P.E.