Harmonized Ground Fault Circuit Interrupters

NORTHBROOK, Ill., - February 6, 2006 - To reduce electrically related deaths and injuries through public education, Underwriters Laboratories Inc. (UL) has joined with the Electrical Safety Foundation International (ESFI), the Canadian Standards Association (CSA), the National Electrical Manufacturers Association (NEMA), and the Consumer Product Safety Commission (CPSC) to disseminate information on new requirements for ground fault circuit interrupters (GFCIs). These new requirements offer a significant safety improvement for consumers.

The new requirements are being set by UL and the CSA and apply to the harmonized standard, UL 943, Safety Standard for Ground Fault Circuit Interrupters (GFCIs) and CSA C22.2 No. 144.1 (Ground Fault Circuit Interrupters).

Since the early 1970s, GFCIs have reduced household electrocutions by protecting residents from lethal currents. A GFCI is a wiring device that de-energizes a circuit when a current to ground could result in electric shock. The GFCI "interrupts" power before it reaches a level that would cause injury. The National Electrical Code® (NEC) requires GFCIs to be used in bathrooms, kitchens, garages, basements, crawlspaces, and outdoors. Similarly, the Canadian Electrical Code (CEC) requires GFCIs to be used in many locations such as bathrooms, outdoors, basic care areas of hospitals, pools, spas, and hot tubs.

Before the introduction of GFCIs, more than 700 people died from household electrocutions each year. As of 2001, that number had been reduced to 400 cases annually. A 2001 field study from UL and the National Electrical Manufacturers Association, however, determined that a small but significant percent of GFCIs, particularly older ones, did not work after several years. This created a demand for more stringent safety features that can alert users when a GFCI malfunctions.

The new UL and CSA requirements include:

  • End of Life Provision: when a GFCI receptacle is incapable of passing its internal test function (it can no longer provide ground fault protection) it will either a) render itself incapable of delivering power, or b) indicate by visual or audible means that the device must be replaced.
  • Reverse Line-Load Miswire: a GFCI will deny power to the receptacle face if it is miswired.

In the United States, manufacturers must stop producing old versions of GFCIs on July 28, 2006, and must introduce new, redesigned GFCIs after that date. Distributors can sell and contractors can install old GFCIs until their supplies run out.

The UL revisions will not affect the NEC, which regulates installations, not products.

In Canada, the selection of the effective date involves a process that has not yet been completed. Once this occurs, the effective date will be included in the Certification Notice announcing the 2006 edition of CSA Standard C22.2 No. 144.1. The CSA revisions will not affect the CEC, which regulates installations, not products. For more information, please contact Robert LaRocca by phone at +1-631-546-2598 or by email at Robert.l.larocca@us.ul.com.

[ View More Newsletters ] [ Please Reply With Your Comments | View Comments | Notify Me When Comments Are Added ]

F o r w a r d   t h i s   N e w s l e t t e r   t o   a   F r i e n d !
Do you have a friend, relative, or colleague who you think would be interested in receiving this free newsletter? If so, we encourage you to forward this message along to them. If you received this email from someone else, and wish to receive your own free issues of our newsletter, sign up today!

C o n t a c t    I n f o r m a t i o n
 

Copyright © 2002, 2003, 2004, 2005 Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Comments
  • "End of Life Provision: when a GFCI receptacle is incapable of passing its internal test function (it can no longer provide ground fault protection) it will either a) render itself incapable of delivering power, or b) indicate by visual or audible means that the device must be replaced. "

    What good would a visible indicator do to alert the average homeowner? Nobody, other than electricians, is going to pay attention to a visible indicator.

    I am a bit disapointed in the fact that the lockout technology has been around for a fairly good amount of time, and yet UL and CSA allowing an alternative to it. :(

    Ryan Jackson

Reply to this comment
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

This newsletter is closed to new comments.

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter