Article 513 Aircraft Hangars - 513.12
 

 
Subject - Article 513 Aircraft Hangars - 513.12
Based on - NEC - 2005 Edition

August 24, 2007
This newsletter was sent to 26626 newsletter subscribers
 

Ask a Question |  Weekly Code GraphicQuizzes |  Free Stuff InstructorsOnline Training Products | Seminars | SubscribeUnsubscribe
[ image1 Post Comments | View Comments | Notify Me When Comments Are Added ] Web Page Version [Printer-Friendly]    

Article 513   Hi Res - Cable/DSL [4197Kb]
VIEWING Video FILE requires
Real Media Player [ FREE ]
  
Aircraft Hangars

513.12 GFCI Protected Receptacles

New section requires GFCI protection for 15 and 20A, 125V receptacles where aircraft might undergo service, repairs, or alterations.

GFCI protection for personnel is required for all 15 and 20A, 125V receptacles used for service and repair operations, such as electrical diagnostic equipment, electrical hand-tools, portable lighting devices, etc. Figure 513-1

Author’s Comment: Personnel servicing and maintaining aircraft use the same hand tools and equipment that are used in commercial garages, which requires GFCI protection.



Figure 513-1
(Click on image to enlarge)

       
 

Click here to post a comment
[ View More Newsletters ] [ Send to a Friend ] [ Post Comments | View Comments | Notify Me When Comments Are Added ]

Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Experiencing a Problem? Click Here

Comments
  • Tools of choice around aircraft are usually air driven to minimize the possibility of fuel vapor ignition due to commutator sparking or other electrical equipment arc. Article 513 makes a lot of sense since wall driven electrical tools and measurement equipment often find their way into a hangar as well. Even though some hangars have epoxy paint floors or other insulating flooring installed over the concrete, often the aircraft are grounded with a ground lead, so it is important that any wall power driven electrical tools or test equipment used around aircraft are GFCI protected, since a serious shock hazard can exist to personnel operating electrical equipment on or in a grounded aircraft if the power source is not GFCI protected.

    Ed Cohn (Electrician and A/P mech)

Reply to this comment
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter