Newsletter Member Needs Help

Mike,
In December of 2005 I had two water leaks in my front yard, caused by pin-hole leaks in my copper water line. The leaks in the pipes were from the street to the house, thus the responsibility to repair was left up to me and not to the water supplier. My home is 4 years old and I do not understand why I should have such a problem with a newer home.

I called a plumber to repair the two leaks and from what he says it appears to be either a problem with bad copper piping or electrical current going through the copper pipes. Because I was not the original owner of the home, but the second owner, the builder said they were not responsible to repair the leaks. Remember, this was back in December of 2005. Well, this week my neighbors on both sides of me have encountered the same problem with water leaks. Although they have not had their problems repaired yet, the plumbers that have looked at their leaks do confirm that it is again, either bad pipes or electric current passing through the pipes. I do have a ground wire running from my electrical box and grounded on the inside to the copper water pipe line.

Also I have found out that all the wiring (i.e. phone, cable, gas, electric) is in a tunnel ditch going across the copper water line from the water meter to my house. I live in Kentucky were the building codes permit such utilities to be tunnel placed as such.

Mike Holt Comment: It's my understanding, based on studies by the American Water Works Association (AWWA), that alternating current flow does not create this problem. I'm willing to change my opinion if someone has a study to support the claim that pin hole leaks can be created in metal piping because of current flow. Do you have any thoughts?

 

[ View More Newsletters ] [ Send to a Friend ] [ Post Comments | View Comments | Notify Me When Comments Are Added ]

Copyright © Mike Holt Enterprises, Inc. All rights reserved.
This article is protected by United States copyright and other intellectual property laws and may not be
displayed or published on the internet without the prior written permission of Mike Holt Enterprises, Inc.

http://www.MikeHolt.com     1-888-NEC-CODE (1-888-632-2633)

Experiencing a Problem? Contact our Webmaster

Comments
  • HERE ARE SOMETHINGS THAT WILL CAUSE PINHOLES IN COPPER PIPE. 1 HIGH RESISTANCE TO GROUND 2 UNBALLANCED LOAD 3 HIGH RESISTANCE NETURAL 4 SOIL PH 5 WRONG TYPE OF COPPER PIPE 6 HIGH MINERAL CONTENT IN WATER 7 NOT REAMING COPPER PIPE DURING INSTLATION 8 CHEMICAL CONTENT IN WATER

    NO 7 IS THE MOST COMMON CAUSE OF PINHOLES.UNREAMED COPPER CAUSES EDDIES IN THE FLOWING WATER AND DOESN'T ALLOW A COATING IF MINERALS TO BUILD UP ON THE INSIDE OF THE PIPE TO PROTECT IT FROM WEAR.

    NO 6 & 8 MINERALS CAN COMBINE AND STICK TO THE INSIDE OF PIPE AND CAUSE DISIMLAR METAL CROSSION

    NO 4 SOIL CONDITIONS CAN EAT UP COPPER COAT PIPE WITH A PROTECTIVE LAYER OF TAR OR OTHER PROTECTIVE COATING

    NO 5 USE ONLY TYPE K COPPER THAT IS MARKED FOR POTABLE WATER SOME FORIEN COPPER DOES NOT MEET ANSI STANDARDS FOR POTABLE WATER HOME DEPOT AND OTHERS SELL THIS BECAUSE IT IS LESS COSTLY

    THE OTHERS CAUSE ELECTROLIS

    DAVID CUNNINHAM PLUMBING AND ELECTRIC