This article was posted 03/27/2012 and is most likely outdated.

Mike Holt - Articles 547 through 590
header
Articles 547 through 590
Based on - NEC - 2011 Edition

Articles 547 through 590 - Based on the 2011 NEC

By Mike Holt for EC&M

Two factors have a tremendous influence on the lifespan of agricultural equipment: dust and moisture.

Dust gets into mechanisms and causes premature wear. With electricity on the scene, dust adds two other dangers: fire and explosion. Dust from hay, grain, and fertilizer is highly flammable. Litter materials (e.g., straw) are also highly flammable. Farm animal excrement may cause corrosive vapors that eat at electrical wiring methods and equipment. Thus, Article 547 includes requirements for dealing with dust and corrosion.

Moisture causes corrosion. Water is present for many reasons, including wash down. Consequently, Article 547 has requirements for wet and damp environments. Additionally, moisture can increase the chances of shocks to livestock due to differences in potential. Therefore, Article 547 requires you to install equipotential planes in concrete floor confinement areas of livestock buildings containing metallic equipment accessible to animals and likely to become energized.

Livestock have a low tolerance to small levels of stray electrical current, which can cause loss of milk production and even fatality. So the NEC contains specific requirements for an equipotential plane in buildings that house livestock.

Previous Code editions said Article 547 applies to areas that:

  • Have excessive dust, or dust with water, and
  • Contain a corrosive atmosphere

Either condition warrants compliance with Article 547. So, the 2011 Revision removes the word “and” and replaces it with “or.” [547.1]

GFCI-protected receptacles

The allowance for non-GFCI protected receptacles was deleted. The 2008 NEC added an allowance for receptacles (for a dedicated load) that aren’t GFCI protected, provided there was a GFCI-protected receptacle within 3 ft of the non-GFCI-protected receptacle.

This baffled many Code users, as this change is the opposite of the changes the 2008 NEC made in 210.8. While exceptions and allowances were being removed from 210.8, Article 547 seemed to be adding them—without justification. GFCI devices open the circuit when there’s more than 6 mA of leakage current. Because listed products should have no more than 0.50 mA of leakage (or 0.75 mA in certain instances), this exception isn’t necessary.

Luminaires and water

An editorial revision was made to the requirements for luminaires in locations subjected to water. In locations that are exposed to water from condensation or from building cleansing water and solution, luminaires must be of the appropriate type. Previous Code editions addressed this by requiring “watertight” luminaires. By changing the rule to require luminaires that are listed as suitable for use in wet locations [547.8], the rule harmonizes with the general rules of Article 410.

Equipotential Plane

The equipotential bonding described in 547.10 is similar to the requirements for bonding swimming pools in 680.26. Both require an 8 AWG or larger copper conductor, but only 680.26 required this conductor to be solid in the previous Code. Section 547.10 now also requires that the bonding conductor be an 8 AWG or larger solid copper conductor in the 2011 NEC.

The special bonding requirements of Article 547 exist because of the sensitivity of livestock to stray voltage/current, especially in wet or damp concrete animal confinement areas.

Typically, the voltage difference between metal parts and the earth is too low to present a shock hazard. However, livestock might detect the voltage difference if they touch metal parts. Although potential differences may not be life threatening to the livestock, it’s been reported that as little as 0.50V RMS can affect milk production.

Methods to establish equipotential planes are described in the American Society of Agricultural and Biological Engineers Standard EP473, Equipotential Planes in Animal Containment Areas. This standard provides the recommendation of a voltage gradient ramp at the entrances of agricultural buildings.

Article 550: Mobile homes, manufactured homes, and mobile home parks

Among dwelling types, mobile homes have the highest rate of fire. Article 550 addresses some of the causes of those fires. Article 550 recognizes that the same structures used for mobile or manufactured homes are also used for nondwelling purposes, such as construction offices or clinics [550.4(A)]. Thus, it excludes those structures from the 100A minimum service requirement.

Article 550 differentiates between a mobile home and a manufactured home, providing different requirements for each. For example, you can’t locate service equipment on a mobile home. However, you can install service equipment on a manufactured home (provided you meet seven conditions). Pay close attention to the definitions in 550.2 to understand the NEC distinctions.

Mobile home and manufactured homes aren’t covered by the same building codes as site-built homes. Instead, they’re covered by HUD standards. According to HUD, both are referred to as manufactured homes; the term “mobile home” hasn’t been used for many years. This disparity between the NEC and HUD terminology can cause confusion, so read Article 550 carefully as you apply it.

Receptacles

The Article 550 requirements for bathroom receptacles [550.13] are similar to those in 406.9(C). Because Article 550 doesn’t receive many Code change proposals, its requirements can easily fall out of synch with similar requirements found elsewhere in the NEC. When somebody makes a proposal to the general rules in the rest of the Code, they typically forget to make a proposal to Article 550.

Section 406.9(C) was recently changed to clarify that not only is a receptacle in a bathtub prohibited, but a receptacle above a bathtub is also prohibited. This change correlates these sections by adding the same text in this rule.

Similarly, 550.25 has been revised to “catch up” to changes made in 210.12.

  • Section 550.25(A) now says AFCIs are defined in Article 100.
  • Section 550.25(B) now requires AFCIs not only in bedrooms, but in all other areas required by 210.12(B). These include family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, and hallways.

Article 555: Marinas and boatyards

Ocean tides rise and fall, while lakes and rivers vary in depth in response to rain. To provide power to a marina or boatyard, you must allow for these variations in water level between the point of use and the power source.

Article 555 begins with the concept of the electrical datum plane. Think of it as a line that marks the beginning of a zone where you simply don’t place electrical equipment. Once you determine where this plane is, don’t locate transformers, connections, or receptacles below that line.

Ground fault protection of main feeder

After being presented with evidence of over 50 deaths and 30 injuries from electrical incidents in marinas and boatyards, the technical committee added a requirement for equipment ground-fault protection.

At first glance, it seems odd that “equipment” level protection instead of “personnel” protection is the requirement [555.3]. A “Class A” GFCI device (for personnel) opens the circuit when the current to ground is between 4 mA and 6 mA, while a GFPE (for equipment) trips somewhere between 30 mA and 100 mA. While this value is too high to directly protect a human from a fatal electric shock, it will open the circuit under most fault conditions. Removing this fault current will in turn protect humans against electrical shock.

Article 590: Temporary Installations

Temporary wiring represents a different standard from normal wiring, but the same rules of workmanship, ampacity, and overcurrent protection apply. It’s just as important to protect construction workers as it is to protect the tenants who will occupy the completed facility.

Temporary wiring must comply with all provisions of the Code, except where specifically addressed in Article 590 [590.2(A)].

Because there are no rules in Article 590 that address receptacles in wet locations, these receptacles must comply with 406.9. The 2011 NEC clarifies this requirement [590.4(D)(2)].

All 15A and 20A receptacles installed in a wet location must be within an enclosure that’s weatherproof when an attachment plug is inserted. For other than one- or two-family dwellings, the outlet box hood must be listed for “extra-duty” use if supported by grade. Nonlocking-type 15A and 20A, 125V and 250V receptacles in a wet location must be listed as weather resistant [406.9(B)(1)].

Exposed plastic surface material of weather-resistant receptacles must have UV resistance to prevent deterioration from sunlight, or ensure that it’s minimal. In testing, receptacles are subjected to temperature cycling from very cold to very warm conditions, and then subjected to additional dielectric testing. The rapid transition from the cold to warm temperatures will change the relative humidity and moisture content on the device, and the dielectric test ensures this won’t create a breakdown of the insulation properties.

GFCI for Personnel

The 2011 Code requires all 15 kW or smaller generators to have GFCI protection for the 125V or 125/250V, single-phase, 15A, 20A, and 30A receptacles installed on them. For generators manufactured or remanufactured prior to January 1, 2011, cord sets or other devices that provide portable GFCI protection may be used [590.6(A)(3)]. Section 590.6 was also rewritten using a list format for easier reading and understandability.

Chapter 5 in retrospect

Articles 547 – 590 are the last half dozen Articles in Chapter 5 and they cover a wide range of applications within the “Special Occupancies” Chapter. Something you may have noticed is the 2011 NEC attempted to make these Articles consistent with changes elsewhere in the NEC. Remember that Chapters 1 through 4 apply to all installations, and the later Chapters are allowed to supplement and modify the requirements of those four in specific types of applications.

 

Image Taken from Mike Holt’s 2011 Understanding the NEC Volume 2 Textbook. To order your copy, please click here, or call 888-632-2633
footer
This newsletter was sent to 20474 Subscribers
Comments
    No comments to display

Get notified when new comments are posted here
* Your Email:
 
        
 
Add Your Comments to this Newsletter
* Your Name:
   Your name will appear under your comments.

* Your Email:
   Your email address is not displayed.
* Comments:

Email Notification Options:
Notify me when a reply is posted to this comment
Notify me whenever a comment is posted to this newsletter